Material Characteristics
Phase | Functional Group | Encapped | Particle Size (µm) | Pore Size (Å) | Surface Area (m2/g) | Carbon Load | |
---|---|---|---|---|---|---|---|
C18 Gravity | Octadecyl | Yes | 1.8, 3, 5 | 110 | 340 | 18 | |
C18 ec | Octadecyl | Yes | 3, 5 | 110 | 340 | 17.5 | |
C8 Gravity | Octyl | Yes | 1.8, 5 | 110 | 340 | 11 | |
C8 ec | Octyl | Yes | 3, 5 | 110 | 340 | 10.5 | |
C18 Pyramid | Octadecyl | Yes | 1.8, 3, 5 | 110 | 340 | 14 | |
C18 Isis | Octadecyl | Yes | 1.8, 3, 5 | 110 | 340 | 20 | |
Sphinx RP | Octadecyl/Phenyl | Yes | 1.8, 3, 5 | 110 | 340 | 15 | |
CN and CN-RP | Cyano | Yes | 3, 5 | 110 | 340 | 7 | |
NH2 and NH2-RP | Amino |
no |
5 | 110 | 340 | 2.5 |
NUCLEODUR® Gravity |
|||
NUCLEODUR® C18 Gravity and C8 Gravity are based on the ultrapure NUCLEODUR silica. The high density bonding of these phases leads to an extended operational pH range (1-11). This can be helpful for improving selectivity in method development and for more challenging applications. | |||
NUCLEODUR® C18 ec and C8 ec |
|||
The NUCLEODUR C18 ec and C8 ec phases are recommended for routine analyses and for scaling up to preparative HPLC. | |||
NUCLEODUR® C18 Isis |
|||
NUCLEODUR C18 Isis is a C18 bonded phase with specially cross-linked surface modification. This polymeric bonding leads to high steric selectivity and is therefore suited for separation of positional and structural isomers and planar/non-planar molecules. The phase has an enhanced pH stability of 1 to 10. Figure below demonstrates the increased steric selectivity of NUCLEODUR C18 Isis for o-terphenyl (non-planar) and triphenylene (planar) compared with a monomerically bonded C18 phase. | |||
|
|||
NUCLEODUR® C18 Pyramid |
|||
NUCLEODUR® C18 Pyramid is a C18 bonded phase with hydrophilic endcapping, designed especially for use with eluents containing up to 100% water. The phase also shows improved retention characteristics for very polar molecules, such as short chain organic acids. | |||
NUCLEODUR® Sphinx RP |
|||
|
|||
NUCLEODUR® Sphinx RP is a bifunctional phase consisting of a well-balanced ratio of octadecyl and phenyl groups covalently bonded to the NUCLEODUR silica. The combination of classical hydrophobic with π-π interactions expands the scope of selectivity in comparison with conventional reversed-phase materials. NUCLEODUR Sphinx RP is particularly suited for the separation of molecules containing aromatic and multiple bonds. It may also outperform standard C18 phases for the separation of polar compounds. Figure below shows a comparison of the separation of flavonoids on three different NUCLEODUR phases. | |||
NUCLEODUR® HILIC |
|||
NUCLEODUR HILIC is a zwitterionic modified stationary phase. The betaine character of the ammonium – sulphonic acid ligands results in an overall neutrally charged, but highly polar surface. This column is ideal for analysing polar analytes such as acids and bases, natural compounds, nucleosides, amino acids, water soluble vitamins etc. Due to its high loadability, NUCLEODUR HILIC is suitable for preparative applications. | |||
NUCLEODUR® 1.8μm Phases |
|||
|
|||
Increase in separation efficiencyAn increase in plate number of approximately 67% in transferring from 3μm to 1.8μm particles offers the possibility of using shorter columns with equal plate numbers, resulting in a decrease in analysis time. Typically, for a 50 x 4.6mm NUCLEODUR C18 Gravity column: 3μm: N ≥ 100,000 plates/m 1.8μm: N ≥ 166,667 plates/m Improvement in resolutionThe use of 1.8μm instead of 3μm particles can lead to an increase in resolution of approximately 30%. This is illustrated in Figure below for the separation of naphthalene and ethylbenzene. |
|||
All of the NUCLEODUR® premium phases are now available in 1.8μm particle sizes. Columns packed with these microspherical particles show improvements in terms of plate numbers, column efficiencies and resolution, compared with their 3μm counterparts. |
|||
Column back pressureThe smaller particle size results in an increased back pressure. However, the high sphericity of the NUCLEODUR particles and their very narrow particle size distribution means that back pressure is kept at a moderate level. In addition, the particles are fractionated in order to limit the increase in back pressure. Nevertheless, the use of columns packed with sub 2μm particles generally makes special demands on the HPLC equipment. Pumps should be designed for pressures of 250 – 1000 bar and the entire system should feature the lowest possible dead volume, for optimum column performance. Higher flow rates and shorter run timesThe optimal flow rate for 1.8μm particles is higher than for 3 and 5μm particles. |
|||
NUCLEODUR® Bulk Material
|
|||
NUCLEODUR® is an ideal material for scaling-up methods due to the availability of a wide range of particle sizes. The material provides a high mechanical bed stability and the narrow particle size distributions provide lower pressure drop due to the absence of fines. The material is reusable even after several cycles of repeated packing. | |||
NUCLEODUR Bulk Phases | ||
---|---|---|
Particle Type | Spherical | |
Particle Size (µm) | 10, 12, 16, 20, 30, 50 | |
Pore Diameter (Å) | 110 | |
Endcapped | Yes | |
Chemistries | Silica, C18 ec | |
pH Range | 1 – 9 |
Contact Hichrom for further information
Partisil Ultrasphere ACT ACE Hichrom HPLC UHPLC SCX C18 HPLC chromatography LC/MS column AMT SILIC Sequant HILIC accessories solvents Chromatography HPLC-Training Tosoh TSK Shodex High Performance Liquid Chromatography HPLC Microsolv HPLC Training
Hichrom Limited – the HicHrOM(E)of chromatography: HPLC Column Manufacturer and Supplier of the world’s largest range of HPLC columns
上海金畔生物科技有限公司提供生命科学研究领域系列产品,包括生化试剂、色谱标准品和实验仪器耗材。主营Lumiprobe Cy系列活性荧光染料;修饰性PEG(Laysan bio、NANOCS、Avanti等进口品牌PEG以及定制合成修饰性聚乙二醇、单分散小分量PEG);WAKO日本和光纯药;日本关东化学Kanto试剂;Megazyme食品分析检测试剂盒、Harlan、Bio-serv品牌的动物饲料;Sigma、Amresco、TCI、MP bio生化试剂;Oxoid、Nissui日水、BD difco、Himedia品牌微生物培养基;免疫诊断试剂包括:Abcam、CST、Santa Cruz、Bethyl抗体;Biolegend流式抗体;Roche、TOYOBO、NEB品牌的酶;中检所、TRC、药典USP、EP、Reagecon标准品;耗材和仪器包括Whatman、Millipore品牌的各种滤膜、滤器和柱子填料等、Hampton蛋白结晶试剂耗材、老鼠软管灌胃针、动物毛发记号笔、Labnet、Bio-Rad伯乐、康宁Corning、Axygen、Falcon 、Eppendorf、Nunc、Nalgene、Nest品牌的培养皿、培养板、离心机、离心管、移液枪及枪头等实验室常用仪器耗材。